How Boise architectural firm CSHQA’s new building saves energy

Boise architectural firm CSHQA completed its move to its new headquarters in early August.

sberg@idahostatesman.comOctober 15, 2013 

  • By the numbers

    $2 million

    Estimated cost of renovation project: 65

    Number of employees stationed at the headquarters: 12

    Number of bike racks provided for employees: 4.6

    Miles of 5/8-inch tubes in the building’s radiant-floor heating and cooling system: 14

    Number of skylights: 5

    Number of prismatic lenses that bring natural light into the building: 20

    Number of fluorescent lights: 9

Saving money on energy wasn’t the only reason CSHQA undertook a $2 million overhaul of an old Downtown warehouse.

There’s a marketing angle as well. The company’s new headquarters at 200 W. Broad St. serves as a sort of showroom for clients.

“The building is showing all kinds of different things that can go into a building,” Business Development Manager K.K. Lipsey says.

The renovation project was a wholesale transformation of the once-abandoned warehouse, which was built in the late 1950s. A bright, open work space with cheery colors and advanced-looking fixtures replaced bare block and brick walls. During the daytime, natural light pours in through large windows and a series of skylights.

Even the ceiling looks different than it did the past few decades. Crews pulled thousands of square feet of insulation out of it, exposing original joists and boards.

One of Boise’s iconic firms, CSHQA took root in 1889. Even before the turn of the 20th century, the company’s founder, a Scotsman named William Campbell, and his partners designed some of Idaho’s best-known buildings, including the Idanha Hotel in Downtown Boise, the Albion Normal School and Boise’s central fire station.

As new partners joined the firm, its name changed to reflect their participation. In 1979, it became Cline Smull Hamill Quintieri Associates. Six years later, the name was shortened to CSHQA. Besides architectural services, the company provides planning and engineering.

On Aug. 1, CSHQA completed its move into the new-old building from the company’s former headquarters in the C.W. Moore Plaza, 250 S. 5th St.

The most impressive innovation at CSHQA’s new home might be its main heating and cooling system. It has no gas or electrical heat and no air conditioning.

Instead, dozens of 5/8-inch tubes run across the length and width of the floor, covered by about 2 inches of concrete. When the system needs heat to maintain room temperature, it pushes a liquid that has absorbed geothermal energy through the tubes. The energy radiates upward through the concrete and heats the building.

The liquid inside the tubes isn’t from Boise’s geothermal wells. Instead, both the geothermal water and tube liquid pass through a device resembling a car radiator that transfers heat to the tube liquid, which contains glycol.

The cooling process is similar. When the outside temperature is too hot, the system pushes regular municipal water through a heat-exchange system to cool the glycol-containing tube liquid, which absorbs heat inside the building, cooling it down.

The drawback to the floor heating and cooling system is that it takes the better part of a day to adjust to big changes. The building has a traditional heating and cooling system to adjust for sudden, large increases and decreases in temperature.

The building has several other technologies that are designed to make it a more enjoyable work space and save energy.

Several collapsible cloth ducts supply fresh air to the interior. Even beyond the material, which makes airflow quieter, the overhead ducts are unusual. Instead of a few big vents distributed over long distances, CSHQA’s ducts have small vents about every 8 inches. The idea is to keep air moving more efficiently without creating drafts.

Another innovation is a system that harvests heat from workers’ computer towers. This one has yet to be installed, but here’s the concept: A valve on the back of the computer will open up when the machine is turned on. A fan will suck air from inside the computer tower into a small duct. That duct will connect to a larger arterial duct that’s pulling in air from several computers in the same area. The arterial duct and several others like it will connect to a few larger conduits. When the weather’s hot, warm air from the computers will vent to the outside. When it’s cold, the air’s heat will be channeled into the main heating and cooling system.

In the long run, CSHQA believes all this technology will save money for the company.

“We could have just renewed our lease (in the old headquarters) and touched up some paint and rebuilt the lobby,” says Ted Isbell, CSHQA’s architect who oversaw the renovation project. “But we wanted a show place, a place to really kind of walk the walk and show everybody what we’re all about.”

•••

Sven Berg: 377-6275

Idaho Statesman is pleased to provide this opportunity to share information, experiences and observations about what's in the news. Some of the comments may be reprinted elsewhere in the site or in the newspaper. We encourage lively, open debate on the issues of the day, and ask that you refrain from profanity, hate speech, personal comments and remarks that are off point. Thank you for taking the time to offer your thoughts.